{"id":17976,"date":"2026-09-10T17:18:00","date_gmt":"2026-09-10T15:18:00","guid":{"rendered":"https:\/\/staging.meytec.eu\/?p=17976"},"modified":"2026-10-24T07:52:24","modified_gmt":"2026-10-24T05:52:24","slug":"orp-probe-for-swimming-pools-everything-you-need-to-know","status":"publish","type":"post","link":"https:\/\/meytec.eu\/en-mt\/blogs\/blog\/orp-probe-for-swimming-pools-everything-you-need-to-know\/","title":{"rendered":"ORP probe for swimming pools: everything you need to know"},"content":{"rendered":"<h2>What is ORP?<\/h2>\n<p>ORP stands for Oxidation-Reduction Potential, also called redox potential. It is a measure of the ability of water to oxidise substances (give up electrons) or reduce them (take up electrons). In an oxidation-reduction process, one molecule loses electrons while the other takes them up.<\/p>\n<p>The ORP value is expressed in millivolts (mV). The higher the ORP value, the stronger the oxidising capacity of the water and therefore the more effective the disinfection. A positive ORP value means that the water has an oxidising effect, which is essential for killing bacteria, viruses and other micro-organisms.<\/p>\n<h2>ORP and swimming pools<\/h2>\n<p>In <a href=\"\/en-mt\/applications\/swimming-pool\/\">swimming pools<\/a>, ORP is used as the primary indicator of the disinfection capacity of the water. The World Health Organization (WHO) has for years regarded ORP as the most important parameter for checking whether water is microbiologically safe to swim in.<\/p>\n<p>The big advantage of ORP over measuring free chlorine is that ORP measures the actual disinfecting power, not just the chlorine concentration. Two swimming pools with the same amount of free chlorine can have a different ORP value, depending on factors such as pH, temperature and the amount of organic material in the water. ORP therefore gives a more direct picture of how effectively the water is being disinfected.<\/p>\n<p>For a safe and well-disinfected swimming pool, an ORP value between 650 and 750 mV is generally recommended. At a value below 650 mV, disinfection is insufficient and bacteria and algae can develop. The ideal ORP value is between 700 and 750 mV, provided the pH remains between 7.0 and 7.6.<\/p>\n<p>An important point to note: ORP is strongly pH-dependent. When the pH rises, the ORP value falls, which means that at a higher pH you need more chlorine to maintain the same disinfecting power.<\/p>\n<h2>How do you measure ORP?<\/h2>\n<p>ORP is measured with an <a href=\"\/en-mt\/probes\/orp-probe\/\">ORP probe<\/a> (also called a redox electrode). This probe consists of a precious metal (platinum or gold) as the measuring electrode and a reference electrode (usually Ag\/AgCl). The measurement is based on the potential difference between these two electrodes.<\/p>\n<p>In practice, the ORP probe is placed in the pool water, often in a flow cell or directly in the pipes. Modern measuring systems also show pH and temperature alongside ORP, giving you a complete picture of the water quality.<\/p>\n<h2>How is disinfectant produced? The difference between liquid chlorine and salt electrolysis<\/h2>\n<p>There are two commonly used ways to disinfect pool water: dosing liquid chlorine and using salt electrolysis.<\/p>\n<p><strong>Liquid chlorine<\/strong> is added to the pool water as a ready-to-use product. This is a proven method that works quickly and directly. A disadvantage is that liquid chlorine often raises the pH, so you have to add pH minus to keep the water in balance. You will also use several drums of chlorine per season, which in itself makes it more expensive than salt electrolysis.<\/p>\n<p><strong>Salt electrolysis<\/strong>, on the other hand, produces chlorine on site. The pool water contains a low concentration of salt (sodium chloride). By means of electrolysis in an electrolysis cell, this salt is converted into chlorine, which then disinfects the water. An important advantage of salt electrolysis is that no storage or transport of liquid chlorine is needed. In addition, a salt electrolysis cell also destroys chloramines, which ensures pleasant water quality.<\/p>\n<p>Both systems ultimately use chlorine as a disinfectant, but the way in which the chlorine is produced and dosed differs. For ORP control it makes no difference in principle: the ORP probe measures the resulting disinfecting power in both cases.<\/p>\n<h2>Swimming pool ORP probe: what is it and how does it work?<\/h2>\n<p>An ORP probe is a sensor that measures the oxidation-reduction potential of the water. The probe consists of a precious metal (platinum or gold) and a reference electrode. When the probe comes into contact with the pool water, a small potential difference arises, which is converted into an mV signal. <\/p>\n<p>The Meytec <a href=\"\/en-mt\/orp-probe-gold.html\">NXG-ORP<\/a> probe is compatible with all common automatic dosing systems on the market that use the standard BNC connection. You can therefore use it as a replacement probe for Hayward, Sugar Valley, Zodiac, Seko, CCEI, Pool Technologie, Avady, Bayrol and more.<\/p>\n<h3>Difference between platinum and gold<\/h3>\n<p>Both platinum and gold are used as the measuring electrode in ORP sensors. The choice between the two depends on the application:<\/p>\n<ul>\n<li><strong>Platinum electrodes<\/strong> are used for oxidising reactions (above 500 mV), such as in swimming pools and spas and in drinking water treatment. These are suitable for liquid chlorine, but less suitable (or unsuitable) for swimming pools with salt electrolysis.<\/li>\n<li><strong>Gold electrodes<\/strong> are used in a wide range of environments, from industry to swimming pools, and measure oxidising reactions from 100mV to 1000mV. ORP probes with a gold sensor are better suited for use in swimming pools with salt electrolysis.<\/li>\n<\/ul>\n<h2>Calibrating an ORP probe<\/h2>\n<p>Calibrating an ORP probe is essential to ensure accurate measurements. Unlike <a href=\"https:\/\/meytec.eu\/en-mt\/ph-probe.html\">pH probes<\/a>, ORP probes need calibration somewhat less often, but you should check them regularly.<\/p>\n<p>Calibration (or verification) is recommended:<\/p>\n<ul>\n<li>When the ORP probe is new<\/li>\n<li>If the probe has not been used for a while (for example after the winter)<\/li>\n<li>After cleaning the probe<\/li>\n<li>If manual test results differ significantly from the probe reading<\/li>\n<li>Annually as part of maintenance<\/li>\n<\/ul>\n<p>The calibration procedure is as follows:<\/p>\n<ol start=\"1\">\n<li>Rinse the ORP probe thoroughly with clean water (tap water or demineralised water is fine).<\/li>\n<li>Pour a small amount of ORP buffer solution into a clean container.<\/li>\n<li>Immerse the probe in the solution and wait until the reading stabilises (max. 2 minutes).<\/li>\n<li>Set the meter to the reference value of the buffer solution (usually around 475 mV).<\/li>\n<li>Rinse the probe after calibration and place it back in the pool water.<\/li>\n<\/ol>\n<p>You must not reuse ORP buffer solution after use; pour it away and never reuse it.<\/p>\n<h2>ORP buffer solutions<\/h2>\n<p>ORP buffer solutions (also called redox calibration solutions) are available in various reference values. The most commonly used are:<\/p>\n<ul>\n<li><strong><a href=\"\/en-mt\/buffer-solutions\/orp-buffer-solution\/orp-475mv\/\">475&nbsp;mV<\/a><\/strong>: this is the most common reference value for swimming pool applications. Meytec offers this buffer solution in 250 ml, 60 ml and 20 ml sachets, specially for ORP meters and controllers in swimming pools, spas and water treatment systems.<\/li>\n<li><strong><a href=\"\/en-mt\/buffer-solutions\/orp-buffer-solution\/orp-468mv\/\">468&nbsp;mV<\/a><\/strong> and <strong><a href=\"\/en-mt\/buffer-solutions\/orp-buffer-solution\/orp-650mv\/\">650&nbsp;mV<\/a><\/strong>: these ORP values are also available, depending on the measuring range and the application.<\/li>\n<\/ul>\n<p>Meytec supplies ORP buffer solutions in various packaging, including 250 ml bottles and handy sachets. For optimal shelf life, it is advisable to pour only a small amount into a clean glass or beaker for each calibration and to close the main bottle immediately after use.<\/p>\n<p>Also take a look at our <a href=\"\/en-mt\/buffer-solutions\/buffer-solutions-ph-orp\/\">calibration packs<\/a>: with these you have everything, including pH and ORP buffer solution for calibrating your dosing system. The pack also includes cleaning and storage solution for electrodes to keep them in good condition.<\/p>\n<h2>Maintaining an ORP probe: cleaning and storage<\/h2>\n<p><a href=\"\/en-mt\/buffer-solutions\/cleaning-solution\/\">Good maintenance of the ORP probe<\/a> is crucial for reliable measurements and a long service life.<\/p>\n<h3>Storage<\/h3>\n<ul>\n<li>Always store the probe moist, in the <a href=\"\/en-mt\/probe-protective-cap.html\">protective cap<\/a>, filled with KCl storage solution.<\/li>\n<li>Never store the probe in distilled or demineralised water. This draws ions out of the reference cell and damages the probe permanently.<\/li>\n<li>Has the probe dried out? Then place it in storage solution for at least an hour (or better: overnight) to rehydrate.<\/li>\n<\/ul>\n<h3>Cleaning<\/h3>\n<ul>\n<li>Rinse the probe with clean water after every use (tap water or demineralised).<\/li>\n<li>Do not use a cloth or brush on the pH glass or the sensitive ORP sensor. Scratches and static charge can permanently damage the probe.<\/li>\n<li>For thorough cleaning, immerse the probe for about 15 minutes in a <a href=\"\/en-mt\/ph-probe-cleaning-solution.html\">cleaning solution for electrodes<\/a>. Meytec offers a special cleaning solution for this.<\/li>\n<li>After cleaning, rinse thoroughly with clean water and, if necessary, let the probe rehydrate for an hour in <a href=\"\/en-mt\/buffer-solutions\/kcl-storage-solution\/\">KCl storage solution<\/a>.<\/li>\n<\/ul>\n<p>With good maintenance and regular calibration, your ORP probe will keep measuring reliably for years, so that your pool water always stays safe and clear. Meytec offers a complete range of ORP probes, buffer solutions, cleaning agents and storage solutions to support you.<\/p>\n<p>Related: pH probe.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A clear and safe swimming pool starts with effective disinfection. In this blog we explain what ORP (oxidation-reduction potential) is, why this value is essential for pool water and how to measure ORP with an ORP probe. We discuss the difference between liquid chlorine and salt electrolysis, the choice between platinum and gold ORP probes, and how to calibrate the ORP probe with ORP buffer solutions.<\/p>\n","protected":false},"author":0,"featured_media":13921,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[549],"tags":[],"class_list":["post-17976","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/posts\/17976","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/comments?post=17976"}],"version-history":[{"count":1,"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/posts\/17976\/revisions"}],"predecessor-version":[{"id":21872,"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/posts\/17976\/revisions\/21872"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/media\/13921"}],"wp:attachment":[{"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/media?parent=17976"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/categories?post=17976"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meytec.eu\/en-mt\/wp-json\/wp\/v2\/tags?post=17976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}