{"id":1466,"count":0,"description":"<h2>pH, EC un ORP elektrodi un kalibr\u0113\u0161anas \u0161\u0137\u012bdumi \u016bdens att\u012br\u012b\u0161an\u0101<\/h2><p>Uzziniet, k\u0101p\u0113c pareizi pH, EC un ORP m\u0113r\u012bjumi ir b\u016btiski efekt\u012bvai \u016bdens att\u012br\u012b\u0161anai. Izlasiet, k\u0101 prec\u012bzi m\u0113r\u012bt ar pH m\u0113r\u012bt\u0101ju, EC m\u0113r\u012bt\u0101ju vai m\u0113r\u012b\u0161anas sist\u0113mu un kuri Meytec elektrodi un kalibr\u0113\u0161anas \u0161\u0137\u012bdumi jums \u0161aj\u0101 darb\u0101 vislab\u0101k pal\u012bdz.<\/p><p>\u016adens att\u012br\u012b\u0161an\u0101 pH, EC un ORP ir tr\u012bs no visvair\u0101k kontrol\u0113tajiem parametriem. pH v\u0113rt\u012bba ietekm\u0113 \u0137\u012bmisk\u0101s reakcijas, koroziju, ka\u013c\u0137akmens nogulsn\u0113\u0161anos un dezinfekcijas l\u012bdzek\u013cu darb\u012bbu. EC v\u0113rt\u012bba (elektrisk\u0101 vad\u012btsp\u0113ja) nor\u0101da iz\u0161\u0137\u012bdu\u0161o s\u0101\u013cu un miner\u0101lvielu kop\u0113jo koncentr\u0101ciju. ORP v\u0113rt\u012bba (oksid\u0113\u0161an\u0101s-reduc\u0113\u0161an\u0101s potenci\u0101ls) m\u0113ra \u016bdens sp\u0113ju oksid\u0113t vai dezinfic\u0113t. Nepareizs pH, EC vai ORP rada neefekt\u012bvus procesus, iek\u0101rtu boj\u0101jumus vai pras\u012bb\u0101m neatbilsto\u0161us notek\u016bde\u0146us.<\/p><h2>K\u0101p\u0113c pH, EC un ORP ir svar\u012bgi \u016bdens att\u012br\u012b\u0161an\u0101?<\/h2><p>pH v\u0113rt\u012bba nor\u0101da, cik sk\u0101bs vai b\u0101zisks ir \u016bdens, skal\u0101 no 0 l\u012bdz 14. EC v\u0113rt\u012bba m\u0113ra vad\u012btsp\u0113ju, kas izteikta \u00b5S\/cm vai mS\/cm. ORP v\u0113rt\u012bbu m\u0113ra milivoltos (mV), un t\u0101 nor\u0101da l\u012bdzsvaru starp oksid\u0113jo\u0161\u0101m un reduc\u0113jo\u0161\u0101m viel\u0101m. Visas tr\u012bs nosaka att\u012br\u012b\u0161anas, doz\u0113\u0161anas un kvalit\u0101tes kontroles efektivit\u0101ti.<\/p><h2>Nepareiza pH, EC vai ORP m\u0113r\u012bjuma sekas<\/h2><ul><li><strong>Korozija un ka\u013c\u0137akmens nogulsnes:<\/strong> nepareizs pH var saboj\u0101t cauru\u013cvadus un iek\u0101rtas.<\/li><li><strong>Neefekt\u012bva dezinfekcija:<\/strong> hlors un citi dezinfekcijas l\u012bdzek\u013ci darbojas optim\u0101li tikai noteikt\u0101 pH diapazon\u0101 un pie pareiza ORP.<\/li><li><strong>Pras\u012bb\u0101m neatbilsto\u0161i notek\u016bde\u0146i:<\/strong> notek\u016bde\u0146i, kas neatbilst novad\u012b\u0161anas norm\u0101m, rada sodus un kait\u0113jumu videi.<\/li><li><strong>Nepareiza doz\u0113\u0161ana:<\/strong> k\u013c\u016bdains EC vai ORP m\u0113r\u012bjums var izrais\u012bt \u0137imik\u0101liju p\u0101rdoz\u0113\u0161anu vai nepietiekamu apstr\u0101di.<\/li><\/ul><p>T\u0101p\u0113c nep\u0101rtraukta uzraudz\u012bba un regul\u0101ra pH, EC un ORP m\u0113r\u012b\u0161ana ir neaizst\u0101jama katr\u0101 \u016bdens att\u012br\u012b\u0161anas iek\u0101rt\u0101.<\/p><h2>K\u0101 m\u0113r\u012bt pH, EC un ORP \u016bdens att\u012br\u012b\u0161an\u0101?<\/h2><ul><li><strong>P\u0101rn\u0113s\u0101jams pH m\u0113r\u012bt\u0101js un EC m\u0113r\u012bt\u0101js (rokas):<\/strong> p\u0101rn\u0113s\u0101jams m\u0113r\u012bt\u0101js ir ide\u0101li piem\u0113rots \u0101tr\u0101m p\u0101rbaud\u0113m uz vietas, paraugu \u0146em\u0161anai vai lauka darbiem. M\u0113r\u012bt\u0101js uzreiz par\u0101da digit\u0101lu v\u0113rt\u012bbu un ir viegli kalibr\u0113jams.<\/li><li><strong>pH, EC un ORP m\u0113r\u012b\u0161anas un regul\u0113\u0161anas sist\u0113ma (elektrodi):<\/strong> stacion\u0101ra sist\u0113ma ir past\u0101v\u012bgi uzst\u0101d\u012bta cauru\u013cvados, baseinos vai reaktoros. <a href=\"\/lv\/elektrodi\/ph-elektrods\/\">pH elektrods<\/a>, EC elektrods un ORP elektrods m\u0113ra nep\u0101rtraukti. Pla\u0161\u0101kas sist\u0113mas var autom\u0101tiski doz\u0113t vai aktiviz\u0113t trauksmi.<\/li><\/ul><p>Ab\u0101s sist\u0113m\u0101s pH elektrods, EC elektrods un ORP elektrods ir jut\u012bg\u0101k\u0101s un kritisk\u0101k\u0101s da\u013cas. Augstas kvalit\u0101tes elektrodi, kas ir pareizi kalibr\u0113ti un kopti, nosaka j\u016bsu m\u0113r\u012bjumu precizit\u0101ti un uzticam\u012bbu.<\/p><h2>pH, EC un ORP elektrodi un m\u0113r\u012bt\u0101ji \u016bdens att\u012br\u012b\u0161anai<\/h2><p>Meytec pied\u0101v\u0101 augstas kvalit\u0101tes risin\u0101jumus abiem m\u0113r\u012b\u0161anas sist\u0113mu veidiem: univers\u0101li sader\u012bgus pH elektrodus, EC elektrodus, ORP elektrodus, p\u0101rn\u0113s\u0101jamus m\u0113r\u012bt\u0101jus un visus nepiecie\u0161amos kalibr\u0113\u0161anas un apkopes \u0161\u0137\u012bdumus.<\/p><h3>pH elektrods \u016bdens att\u012br\u012b\u0161anai<\/h3><p>Daudzas \u016bdens att\u012br\u012b\u0161anas iek\u0101rtas jau str\u0101d\u0101 ar paz\u012bstamu z\u012bmolu pH m\u0113r\u012bt\u0101jiem vai ieb\u016bv\u0113t\u0101m sist\u0113m\u0101m. Meytec pied\u0101v\u0101 univers\u0101lus pH elektrodus ar standarta BNC savienot\u0101ju, kas der liel\u0101kajai da\u013cai iek\u0101rtu. P\u0101rbaudiet, vai j\u016bsu ier\u012bcei ir BNC ieeja. T\u0101 j\u016bs nomain\u0101t tikai nolietoto elektrodu, un j\u016bsu eso\u0161\u0101 sist\u0113ma turpina optim\u0101li darboties. Skatiet pH elektrodu.<\/p><p>M\u016bsu pH elektrodi ir piem\u0113roti dzeramajam \u016bdenim, notek\u016bde\u0146iem, procesa \u016bdenim un dzes\u0113\u0161anas \u016bdenim.<\/p><h3>EC elektrods \u016bdens att\u012br\u012b\u0161anai<\/h3><p>Ar\u012b EC m\u0113r\u012b\u0161anai Meytec pied\u0101v\u0101 rezerves EC elektrodus. P\u0101rbaudiet savienot\u0101ju. T\u0101 j\u016bsu EC m\u0113r\u012b\u0161anas sist\u0113ma paliek uzticama, un jums nav j\u0101ieg\u0101d\u0101jas piln\u012bgi jauns sensors. Skatiet <a href=\"\/lv\/elektrodi\/\">elektrodus<\/a>.<\/p><h3>ORP elektrods \u016bdens att\u012br\u012b\u0161anai<\/h3><p>Dezinfekcijas kontrolei Meytec pieg\u0101d\u0101 ORP elektrodus ar zeltu un standarta BNC. M\u016bsu ORP elektrodi ir piem\u0113roti hlora, ozona vai citu oksid\u0101cijas procesu nep\u0101rtrauktai m\u0113r\u012b\u0161anai. Skatiet <a href=\"\/lv\/elektrodi\/orp-elektrods\/\">ORP elektrodu<\/a>.<\/p><h3>pH m\u0113r\u012bt\u0101js un EC m\u0113r\u012bt\u0101js \u016bdens att\u012br\u012b\u0161anai<\/h3><p>L\u012bdz\u0101s atsevi\u0161\u0137iem elektrodiem Meytec pied\u0101v\u0101 ar\u012b pilnus p\u0101rn\u0113s\u0101jamus pH m\u0113r\u012bt\u0101jus un EC m\u0113r\u012bt\u0101jus. Tie ir viegli kalibr\u0113jami un gatavi lieto\u0161anai dzeramaj\u0101 \u016bden\u012b, notek\u016bde\u0146os vai procesa \u016bden\u012b. Ide\u0101li piem\u0113roti \u0101tr\u0101m p\u0101rbaud\u0113m vai paraugu \u0146em\u0161anai. Skatiet <a href=\"\/lv\/meritaji\/ph-meritajs\/\">pH m\u0113r\u012bt\u0101ju<\/a>.<\/p><h2>pH, EC un ORP kalibr\u0113\u0161anas \u0161\u0137\u012bdumi<\/h2><p>pH elektrods, EC elektrods un ORP elektrods ir jut\u012bgi sensori, kas regul\u0101ri j\u0101kalibr\u0113. \u0160im nol\u016bkam izmantojiet tikai kalibr\u0113\u0161anas \u0161\u0137\u012bdumus ar zin\u0101m\u0101m v\u0113rt\u012bb\u0101m. Meytec pied\u0101v\u0101:<\/p><ul><li>pH kalibr\u0113\u0161anas \u0161\u0137\u012bdumi: <a href=\"\/lv\/kalibresanas-skidumi\/ph-kalibresanas-skidums\/ph-4\/\">pH 4<\/a>, <a href=\"\/lv\/kalibresanas-skidumi\/ph-kalibresanas-skidums\/ph-7\/\">pH 7<\/a> un <a href=\"\/lv\/kalibresanas-skidumi\/ph-kalibresanas-skidums\/ph-10\/\">pH 10<\/a>, pieejami 20 ml, 60 ml un 250 ml iepakojumos.<\/li><li>EC kalibr\u0113\u0161anas \u0161\u0137\u012bdumi: <a href=\"\/lv\/kalibresanas-skidumi\/ec-kalibresanas-skidums\/ec-1413-s-cm\/\">1413 \u00b5S\/cm<\/a> zemajam diapazonam un <a href=\"\/lv\/kalibresanas-skidumi\/ec-kalibresanas-skidums\/ec-12880-s-cm\/\">12880 \u00b5S\/cm<\/a> augstajam diapazonam. To nosaka j\u016bsu m\u0113r\u012bt\u0101ja lieto\u0161anas instrukcija.<\/li><li>ORP kalibr\u0113\u0161anas \u0161\u0137\u012bdumi: parasti <a href=\"\/lv\/kalibresanas-skidumi\/orp-kalibresanas-skidums\/orp-475mv\/\">475 mV<\/a>, pieejami ar\u012b 250 mV, 468 mV un 650 mV.<\/li><\/ul><p>Kalibr\u0113jiet vismaz reizi ned\u0113\u013c\u0101 vai bie\u017e\u0101k intens\u012bvas lieto\u0161anas gad\u012bjum\u0101 vai tad, ja ir aizdomas par novirz\u0113m v\u0113rt\u012bb\u0101s.<\/p><h3>pH, EC un ORP elektrodu t\u012br\u012b\u0161ana<\/h3><p>\u016adens att\u012br\u012b\u0161an\u0101 uz elektrodiem var nos\u0113sties ka\u013c\u0137akmens, dzelzs nogulsnes, tauki vai biopl\u0113ve. Tas samazina reakciju un precizit\u0101ti. Nekad neizmantojiet agres\u012bvus t\u012br\u012b\u0161anas l\u012bdzek\u013cus vai abraz\u012bvus l\u012bdzek\u013cus, bet t\u012briet elektrodus ar speci\u0101lu Meytec <a href=\"\/lv\/kalibresanas-skidumi\/tirisanas-skidums\/\">t\u012br\u012b\u0161anas \u0161\u0137\u012bdumu<\/a> elektrodiem.<\/p><p>Notur\u012bgu nogul\u0161\u0146u gad\u012bjum\u0101 var izmantot m\u012bkstu birst\u012bti, bet tikai kop\u0101 ar t\u012br\u012b\u0161anas \u0161\u0137\u012bdumu. P\u0113c t\u012br\u012b\u0161anas r\u016bp\u012bgi noskalojiet ar demineraliz\u0113tu \u016bdeni un kalibr\u0113jiet no jauna.<\/p><h3>pH, EC un ORP elektrodu uzglab\u0101\u0161ana<\/h3><p>pH elektrodu un ORP elektrodu nekad nedr\u012bkst uzglab\u0101t sausus. Uzglab\u0101jiet tos <a href=\"\/lv\/elektroda-aizsargvacins.html\">aizsargv\u0101ci\u0146\u0101<\/a>, kas piepild\u012bts ar <a href=\"\/lv\/kalibresanas-skidumi\/kcl-uzglabasanas-skidums\/\">KCl 3 mol\/l uzglab\u0101\u0161anas \u0161\u0137\u012bdumu<\/a>. Meytec pieg\u0101d\u0101 \u0161o uzglab\u0101\u0161anas \u0161\u0137\u012bdumu.<\/p><p>EC elektrodus parasti uzglab\u0101 sausus. Vispirms noskalojiet tos ar demineraliz\u0113tu \u016bdeni, lai nov\u0113rstu s\u0101ls nogulsnes. Nekad neuzglab\u0101jiet elektrodus kr\u0101na \u016bden\u012b.<\/p><p>Past\u0101v\u012bgi str\u0101d\u0101jo\u0161\u0101s stacion\u0101r\u0101s sist\u0113m\u0101s ieteicams pH un ORP elektrodu \u012bsu apkopes p\u0101rtraukumu laik\u0101 uz laiku ievietot uzglab\u0101\u0161anas \u0161\u0137\u012bdum\u0101.<\/p><p>Ar labu apkopi un pareiziem Meytec \u0161\u0137\u012bdumiem j\u016bsu pH, EC un ORP elektrodi kalpo ilg\u0101k un j\u016bsu m\u0113r\u012b\u0161anas sist\u0113ma paliek uzticama.<\/p><h2>pH, EC un ORP elektroda nomai\u0146a \u016bdens att\u012br\u012b\u0161an\u0101<\/h2><h3>pH elektrods Hach<\/h3><p>Hach HQ s\u0113rija un ieb\u016bv\u0113tie pH sensori. P\u0101rbaudiet, vai j\u016bsu ier\u012bce pie\u013cauj BNC. Meytec pieg\u0101d\u0101 tiem piem\u0113rotus rezerves pH elektrodus.<\/p><h3>EC elektrods Hach<\/h3><p>Hach HQ s\u0113rija un ieb\u016bv\u0113tie EC sensori dzeramajam \u016bdenim un notek\u016bde\u0146iem. Meytec pied\u0101v\u0101 tiem piem\u0113rotus EC elektrodus.<\/p><h3>ORP elektrods Hach<\/h3><p>Hach HQ s\u0113rija un ieb\u016bv\u0113tie ORP sensori dezinfekcijas kontrolei. Meytec pieg\u0101d\u0101 tiem piem\u0113rotus ORP elektrodus.<\/p><h3>pH elektrods Endress+Hauser<\/h3><p>Endress+Hauser pH sist\u0113mas procesu un \u016bdens att\u012br\u012b\u0161anai. P\u0101rbaudiet savienot\u0101ju. Meytec pieg\u0101d\u0101 t\u0101m piem\u0113rotus pH elektrodus.<\/p><h3>EC elektrods Endress+Hauser<\/h3><p>Endress+Hauser EC sist\u0113mas procesu kontrolei. Meytec pied\u0101v\u0101 t\u0101m piem\u0113rotus EC elektrodus.<\/p><h3>ORP elektrods Endress+Hauser<\/h3><p>Endress+Hauser ORP sist\u0113mas dezinfekcijai un oksid\u0101cijai. Meytec pieg\u0101d\u0101 t\u0101m piem\u0113rotus ORP elektrodus.<\/p><h3>pH elektrods WTW<\/h3><p>WTW inoLab s\u0113rija un MultiLine sist\u0113mas. P\u0101rbaudiet, vai j\u016bsu ier\u012bce pie\u013cauj BNC. Meytec pieg\u0101d\u0101 rezerves pH elektrodus m\u0113r\u012b\u0161anas sist\u0113m\u0101m ar standarta BNC.<\/p><h3>EC elektrods WTW<\/h3><p>WTW EC m\u0113r\u012bt\u0101ji un sensori lieto\u0161anai laboratorij\u0101 un uz lauka. Meytec pied\u0101v\u0101 tiem piem\u0113rotus EC elektrodus.<\/p><h3>ORP elektrods WTW<\/h3><p>WTW ORP m\u0113r\u012bt\u0101ji un sensori \u016bdens att\u012br\u012b\u0161anai. Meytec pieg\u0101d\u0101 tiem piem\u0113rotus ORP elektrodus.<\/p><h3>pH elektrods Mettler Toledo<\/h3><p>Mettler Toledo pH sist\u0113mas profesion\u0101lai \u016bdens att\u012br\u012b\u0161anai. P\u0101rbaudiet, vai j\u016bsu ier\u012bce pie\u013cauj BNC. Meytec pieg\u0101d\u0101 t\u0101m piem\u0113rotus rezerves pH elektrodus.<\/p><h3>EC elektrods Mettler Toledo<\/h3><p>Mettler Toledo EC sist\u0113mas procesu kontrolei. Meytec pied\u0101v\u0101 t\u0101m piem\u0113rotus EC elektrodus.<\/p><h3>ORP elektrods Mettler Toledo<\/h3><p>Mettler Toledo ORP sist\u0113mas procesu kontrolei un dezinfekcijai. Meytec pieg\u0101d\u0101 t\u0101m piem\u0113rotus ORP elektrodus.<\/p><h3>pH elektrods Hamilton<\/h3><p>Hamilton pH sensori procesu un \u016bdens att\u012br\u012b\u0161anai. P\u0101rbaudiet savienot\u0101ju. Meytec pieg\u0101d\u0101 tiem piem\u0113rotus pH elektrodus.<\/p><h3>EC elektrods Hamilton<\/h3><p>Hamilton EC sensori procesu kontrolei. Meytec pied\u0101v\u0101 tiem piem\u0113rotus EC elektrodus.<\/p><h3>ORP elektrods Hamilton<\/h3><p>Hamilton ORP sensori dezinfekcijai un oksid\u0101cijas procesiem. Meytec pieg\u0101d\u0101 tiem piem\u0113rotus ORP elektrodus.<\/p><h2>Secin\u0101jums<\/h2><p>Pareizs pH, EC un ORP m\u0113r\u012bjums ir efekt\u012bvas \u016bdens att\u012br\u012b\u0161anas pamats. Neatkar\u012bgi no t\u0101, vai izmantojat p\u0101rn\u0113s\u0101jamu m\u0113r\u012bt\u0101ju \u0101tr\u0101m p\u0101rbaud\u0113m vai stacion\u0101ru m\u0113r\u012b\u0161anas sist\u0113mu nep\u0101rtrauktai uzraudz\u012bbai, iz\u0161\u0137iro\u0161a ir elektrodu kvalit\u0101te un to apkope. Ar Meytec pH elektrodiem, EC elektrodiem, ORP elektrodiem, m\u0113r\u012bt\u0101jiem un kalibr\u0113\u0161anas \u0161\u0137\u012bdumiem j\u016bs uzturat savus procesus prec\u012bzus un uzticamus.<\/p><p>Pas\u016btiet elektrodu vai m\u0113r\u012bt\u0101ju, kas nepiecie\u0161ams j\u016bsu \u016bdens att\u012br\u012b\u0161anas iek\u0101rtai. V\u0113l jaut\u0101jumi? <a href=\"\/lv\/klientu-apkalposana\/\">Sazinieties ar mums<\/a>. \u0100tra pieg\u0101de Latvij\u0101.<\/p><\/article>","link":"https:\/\/meytec.eu\/lv\/lietojumi\/udens-attirisana\/","name":"Kalibr\u0113\u0161anas \u0161\u0137\u012bdumi | \u016bdens att\u012br\u012b\u0161ana","slug":"udens-attirisana","taxonomy":"product_cat","parent":1450,"meta":[],"menu_order":0,"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/meytec.eu\/lv\/wp-json\/wp\/v2\/product_cat\/1466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meytec.eu\/lv\/wp-json\/wp\/v2\/product_cat"}],"about":[{"href":"https:\/\/meytec.eu\/lv\/wp-json\/wp\/v2\/taxonomies\/product_cat"}],"up":[{"embeddable":true,"href":"https:\/\/meytec.eu\/lv\/wp-json\/wp\/v2\/product_cat\/1450"}],"wp:post_type":[{"href":"https:\/\/meytec.eu\/lv\/wp-json\/wp\/v2\/product?product_cat=1466"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}