{"id":14935,"date":"2025-10-19T15:44:00","date_gmt":"2025-10-19T13:44:00","guid":{"rendered":"https:\/\/staging.meytec.eu\/onderhoud-van-ph-en-orp-elektroden-zo-houd-je-je-m\/"},"modified":"2026-10-21T15:30:32","modified_gmt":"2026-10-21T13:30:32","slug":"udrzba-ph-a-orp-sond-ako-udrzat-spolahlive-merania","status":"publish","type":"post","link":"https:\/\/meytec.eu\/sk\/blogs\/blog\/udrzba-ph-a-orp-sond-ako-udrzat-spolahlive-merania\/","title":{"rendered":"\u00dadr\u017eba pH a ORP sond: ako udr\u017ea\u0165 spo\u013eahliv\u00e9 merania"},"content":{"rendered":"<h2>\u010co s\u00fa pH a ORP sondy?<\/h2>\n<p><strong><a href=\"\/sk\/sondy-ph-orp-a-ec\/ph-sonda\/\">pH elektr\u00f3da<\/a><\/strong> meria kyslos\u0165 vody. V <a href=\"\/sk\/pouzitie\/bazen\/\">baz\u00e9noch<\/a> je pH medzi 7,0 a 7,6 ide\u00e1lne pre pohodlie plavcov aj pre \u00fa\u010dinnos\u0165 chl\u00f3ru. V <a href=\"\/sk\/pouzitie\/akvarium\/\">akv\u00e1ri\u00e1ch<\/a> je stabiln\u00e9 pH k\u013e\u00fa\u010dov\u00e9 pre zdravie r\u00fdb a rastl\u00edn.<\/p>\n<p><strong><a href=\"\/sk\/sondy-ph-orp-a-ec\/orp-sonda\/\">ORP elektr\u00f3da<\/a><\/strong> (redox) meria oxida\u010dno-reduk\u010dn\u00fd potenci\u00e1l vyjadren\u00fd v milivoltoch (mV). T\u00e1to hodnota ud\u00e1va, ako silno voda oxiduje, a teda ak\u00e1 \u00fa\u010dinn\u00e1 je dezinfekcia. V baz\u00e9noch sa pre bezpe\u010dn\u00fa vodu na k\u00fapanie odpor\u00fa\u010da ORP medzi 650 a 750 mV.<\/p>\n<p>Obe elektr\u00f3dy pracuj\u00fa so sklenenou membr\u00e1nou (pH) alebo s u\u0161\u013eachtil\u00fdm kovom, ako je platina alebo zlato (ORP), v kombin\u00e1cii s referen\u010dnou elektr\u00f3dou. S\u00fa preto citliv\u00e9 na zne\u010distenie a vysychanie.<\/p>\n<h2>Pre\u010do je \u00fadr\u017eba potrebn\u00e1<\/h2>\n<p>pH a ORP elektr\u00f3dy meraj\u00fa spo\u013eahlivo len vtedy, ak s\u00fa sklenen\u00e1 membr\u00e1na a referen\u010dn\u00e1 diafragma \u010dist\u00e9, hydratovan\u00e9 a nepo\u0161koden\u00e9. Zl\u00e1 \u00fadr\u017eba vedie k pomal\u00fdm reakci\u00e1m, odch\u00fdlnym hodnot\u00e1m a krat\u0161ej \u017eivotnosti.<\/p>\n<p>V baz\u00e9noch a akv\u00e1ri\u00e1ch s\u00fa elektr\u00f3dy vystaven\u00e9:<\/p>\n<ul>\n<li><strong>vodn\u00e9mu kame\u0148u<\/strong> z tvrdej vody<\/li>\n<li><strong>tukom a organick\u00fdm ne\u010distot\u00e1m<\/strong> (ko\u017en\u00fd maz, opa\u013eovac\u00ed kr\u00e9m, krmivo pre ryby)<\/li>\n<li><strong>riasam a biofilmu<\/strong> v teplom, vlhkom prostred\u00ed<\/li>\n<li><strong>vyschnutiu<\/strong>, ak sa elektr\u00f3da neuchov\u00e1va vo vlhku<\/li>\n<\/ul>\n<p>V\u00fdsledok? Offset a strmos\u0165 elektr\u00f3dy sa pos\u00favaj\u00fa, tak\u017ee va\u0161e merania sa pomaly, ale isto st\u00e1vaj\u00fa nespo\u013eahliv\u00fdmi.<\/p>\n<p><strong>V\u00fdhody spr\u00e1vnej \u00fadr\u017eby:<\/strong><\/p>\n<ul>\n<li>Stabiln\u00e9, reprodukovate\u013en\u00e9 nameran\u00e9 hodnoty<\/li>\n<li>Krat\u0161\u00ed \u010das odozvy<\/li>\n<li>Dlh\u0161ia \u017eivotnos\u0165 elektr\u00f3dy<\/li>\n<li>Menej chybn\u00fdch meran\u00ed a zbyto\u010dn\u00fdch korekci\u00ed<\/li>\n<\/ul>\n<h2>Ako \u010disti\u0165 pH a ORP sondy?<\/h2>\n<p>\u010cistenie je jednoduch\u00e9, ale mus\u00edte postupova\u0165 opatrne. Sklenen\u00e1 membr\u00e1na pH elektr\u00f3dy a citliv\u00fd ORP senzor s\u00fa krehk\u00e9.<\/p>\n<p><strong>Pre\u010do je \u010distenie naozaj potrebn\u00e9<\/strong><br \/>pH alebo ORP elektr\u00f3da je elektrochemick\u00fd senzor. Meranie prebieha na povrchu sklenenej membr\u00e1ny (pH) alebo platinovej\/zlatej meracej elektr\u00f3dy (ORP). Hne\u010f ako sa tam vytvor\u00ed vrstvi\u010dka vodn\u00e9ho kame\u0148a, tuku, bielkov\u00edn alebo biofilmu, merac\u00ed povrch sa od vody izoluje. N\u00e1sledok: pomal\u00e9 reak\u010dn\u00e9 \u010dasy, odch\u00fdlne hodnoty a offset mimo povolenej tolerancie.<\/p>\n<p><strong>Ako funguje \u010distiaci roztok<\/strong><br \/>\u010cistiace roztoky na elektr\u00f3dy rie\u0161ia tento probl\u00e9m dvoma sp\u00f4sobmi:<\/p>\n<ol start=\"1\">\n<li><strong>Rozp\u00fa\u0161\u0165anie miner\u00e1lnych usaden\u00edn (vodn\u00e9ho kame\u0148a)<\/strong><br \/>Vodn\u00fd kame\u0148 (uhli\u010ditan v\u00e1penat\u00fd) sa vo vode nerozp\u00fa\u0161\u0165a. \u010cistiace roztoky preto obsahuj\u00fa miernu kyselinu alebo chelata\u010dn\u00fa zl\u00fa\u010deninu, ktor\u00e1 via\u017ee i\u00f3ny v\u00e1pnika a hor\u010d\u00edka. V\u00fdsledkom je, \u017ee sa vrstva vodn\u00e9ho kame\u0148a rozpust\u00ed bez naru\u0161enia skla alebo referen\u010dnej diafragmy. Pri univerz\u00e1lnom \u010distiacom roztoku trv\u00e1 toto p\u00f4sobenie zvy\u010dajne 15 min\u00fat.<\/li>\n<li><strong>Odstra\u0148ovanie tukov, bielkov\u00edn a organick\u00e9ho materi\u00e1lu<\/strong><br \/>Tukov\u00e9 a bielkovinov\u00e9 ne\u010distoty (ko\u017en\u00fd maz, opa\u013eovac\u00ed kr\u00e9m, krmivo pre ryby, riasy) pri\u013en\u00fa k meraciemu povrchu hydrof\u00f3bnymi v\u00e4zbami. \u010cistiace roztoky obsahuj\u00fa povrchovo akt\u00edvne l\u00e1tky, ktor\u00e9 tieto v\u00e4zby rozru\u0161ia a ne\u010distoty preved\u00fa do roztoku. Pre \u0161pecifick\u00e9 pou\u017eitia existuj\u00fa samostatn\u00e9 \u010distiace prostriedky: odstra\u0148ova\u010d bielkov\u00edn pre akv\u00e1ri\u00e1 s ve\u013ek\u00fdm mno\u017estvom krmiva, odmas\u0165ova\u010d pre baz\u00e9ny s ve\u013ek\u00fdm mno\u017estvom opa\u013eovacieho kr\u00e9mu a z\u00e1sadit\u00e9 \u010distiace prostriedky na zvy\u0161ky m\u00e4sa a tukov.<\/li>\n<\/ol>\n<p><strong>Krok 1: Opl\u00e1chnutie po ka\u017edom pou\u017eit\u00ed<\/strong><br \/>Elektr\u00f3du v\u017edy opl\u00e1chnite \u010distou vodou (vodou z vodovodu alebo demineralizovanou). T\u00fdm odstr\u00e1nite bezprostredn\u00e9 ne\u010distoty a zabr\u00e1nite hromadeniu zvy\u0161kov.<\/p>\n<p><strong>Krok 2: \u010cistiaci roztok pri odoln\u00fdch usadenin\u00e1ch<\/strong><br \/>Elektr\u00f3du ponorte asi na 15 min\u00fat do \u0161peci\u00e1lneho <a href=\"\/sk\/cistiaci-roztok-ph-sonda.html\">\u010distiaceho roztoku na elektr\u00f3dy<\/a>. \u00da\u010dinne odstr\u00e1ni vodn\u00fd kame\u0148, tuky a biofilm. Meytec na to pon\u00faka \u010distiaci roztok vyvinut\u00fd \u0161peci\u00e1lne pre pH a ORP elektr\u00f3dy.<\/p>\n<p><strong>Krok 3: D\u00f4kladn\u00e9 opl\u00e1chnutie a v pr\u00edpade potreby rehydrat\u00e1cia<\/strong><br \/>Po vy\u010disten\u00ed elektr\u00f3du d\u00f4kladne opl\u00e1chnite \u010distou vodou. Je elektr\u00f3da ve\u013emi vysu\u0161en\u00e1? Potom ju na hodinu vlo\u017ete do <a href=\"\/sk\/kalibracne-roztoky\/uchovavaci-roztok-kcl\/\">uchov\u00e1vacieho roztoku KCl<\/a>, aby sa rehydratovala.<\/p>\n<p><strong>Pre\u010do ju jednoducho neutrie\u0165 handri\u010dkou?<\/strong><br \/>Trenie handri\u010dkou alebo kefkou m\u00f4\u017ee na pH skle vytvori\u0165 mikroskopick\u00e9 \u0161krabance. Ka\u017ed\u00fd \u0161krabanec men\u00ed elektrick\u00e9 vlastnosti membr\u00e1ny a sp\u00f4sobuje chyby merania. Statick\u00fd n\u00e1boj na handri\u010dke m\u00f4\u017ee navy\u0161e naru\u0161i\u0165 citliv\u00e9 meranie. \u010cistiaci roztok urob\u00ed pr\u00e1cu bez mechanick\u00e9ho nam\u00e1hania.<\/p>\n<p><strong>Pre\u010do kalibrova\u0165 po \u010disten\u00ed?<\/strong><br \/>Pri kalibr\u00e1cii pr\u00edstroj predpoklad\u00e1, \u017ee elektr\u00f3da je \u010dist\u00e1. Ak je na meracom povrchu e\u0161te vrstvi\u010dka ne\u010dist\u00f4t, kalibra\u010dn\u00e1 krivka sa stanov\u00ed na zne\u010distenom povrchu. Hne\u010f ako sa tieto ne\u010distoty nesk\u00f4r uvo\u013enia, kalibr\u00e1cia u\u017e neplat\u00ed. Ak najprv vy\u010dist\u00edte a potom kalibrujete, m\u00e1te istotu, \u017ee offset a strmos\u0165 s\u00fa spr\u00e1vne.<\/p>\n<h2>Ako uchov\u00e1va\u0165 pH a ORP sondy?<\/h2>\n<p>Uchov\u00e1vanie je mo\u017eno e\u0161te d\u00f4le\u017eitej\u0161ie ne\u017e \u010distenie. Nespr\u00e1vne uchov\u00e1van\u00e1 elektr\u00f3da sa m\u00f4\u017ee v priebehu nieko\u013ek\u00fdch dn\u00ed trvalo po\u0161kodi\u0165.<\/p>\n<p><strong>V\u017edy uchov\u00e1vajte vo vlhku<\/strong><br \/>Sklenen\u00e1 banka (pH) a referen\u010dn\u00e1 diafragma (pH a ORP) musia zosta\u0165 v\u017edy vlhk\u00e9. Elektr\u00f3du v\u017edy uchov\u00e1vajte v <a href=\"\/sk\/ochranny-kryt-sondy-ph-orp.html\">ochrannom kryte<\/a> naplnenom uchov\u00e1vac\u00edm roztokom KCl 3&nbsp;mol\/l.<\/p>\n<p><strong>Ako presne funguje uchov\u00e1vac\u00ed roztok<\/strong><br \/>Uchov\u00e1vac\u00ed roztok, zn\u00e1my aj ako 3 mol\/L roztok KCl, rob\u00ed tri veci naraz:<\/p>\n<ol start=\"1\">\n<li><strong>Udr\u017eiava sklenen\u00fa membr\u00e1nu hydratovan\u00fa<\/strong><br \/>pH sklo elektr\u00f3dy je pokryt\u00e9 takzvanou <strong>hydratovanou vrstvou<\/strong> (swelling layer). Je to ultratenk\u00e1 vrstvi\u010dka s hr\u00fabkou asi 0,1 mikr\u00f3nov, do ktorej m\u00f4\u017eu prenika\u0165 vod\u00edkov\u00e9 i\u00f3ny (H\u207a) a vytv\u00e1ra\u0165 tak rozdiel potenci\u00e1lov, ktor\u00fd ur\u010duje pH. T\u00e1to vrstva mus\u00ed zosta\u0165 neust\u00e1le mokr\u00e1. Ak elektr\u00f3da vyschne, hydratovan\u00e1 vrstva zmizne a bez nej elektr\u00f3da u\u017e nemeria. Uchov\u00e1vac\u00ed roztok t\u00fato vrstvu udr\u017eiava neporu\u0161en\u00fa.<\/li>\n<li><strong>Udr\u017eiava referen\u010dn\u00fa diafragmu priechodn\u00fa a stabiln\u00fa<\/strong><br \/>Referen\u010dn\u00e1 elektr\u00f3da (Ag\/AgCl) je cez por\u00e9znu diafragmu v kontakte s meranou vodou. Cez t\u00fato diafragmu neust\u00e1le unik\u00e1 mal\u00e9 mno\u017estvo KCl von. Ak sa elektr\u00f3da uchov\u00e1va v destilovanej vode, vznik\u00e1 osmotick\u00fd efekt: koncentrovan\u00fd KCl v referen\u010dnej cele difunduje do vody, i\u00f3nov\u00e1 sila v referencii kles\u00e1 a referen\u010dn\u00fd potenci\u00e1l sa pos\u00fava. V\u00fdsledkom je trval\u00e1 odch\u00fdlka. Uchov\u00e1vac\u00ed roztok s 3 mol\/L KCl m\u00e1 rovnak\u00fa i\u00f3nov\u00fa silu ako vn\u00fatorn\u00fd referen\u010dn\u00fd roztok. Nevznik\u00e1 potom \u017eiadny osmotick\u00fd tlak a diafragma zost\u00e1va priechodn\u00e1 a stabiln\u00e1.<\/li>\n<li><strong>Zachov\u00e1va spr\u00e1vnu i\u00f3nov\u00fa rovnov\u00e1hu<\/strong><br \/>KCl sa pou\u017e\u00edva preto, lebo i\u00f3ny drasl\u00edka (K\u207a) a chloridu (Cl\u207b) maj\u00fa takmer rovnak\u00fa pohyblivos\u0165. Na diafragme preto vznik\u00e1 len minim\u00e1lny dif\u00fazny potenci\u00e1l. In\u00e9 soli, napr\u00edklad NaCl, by sp\u00f4sobili merate\u013en\u00fa odch\u00fdlku.<\/li>\n<\/ol>\n<p><strong>Nikdy v destilovanej vode<\/strong><br \/>Elektr\u00f3du nikdy neuchov\u00e1vajte v destilovanej ani demineralizovanej vode. Vy\u0165ahuje i\u00f3ny z referen\u010dnej cely a elektr\u00f3du trvalo po\u0161kodzuje. Navy\u0161e sa r\u00fdchlej\u0161ie odparuje, tak\u017ee sklo vysych\u00e1.<\/p>\n<p><strong>Vysu\u0161en\u00e1 elektr\u00f3da?<\/strong><br \/>Ak elektr\u00f3da predsa len vyschla, vlo\u017ete ju aspo\u0148 na hodinu \u2014 ale rad\u0161ej na noc \u2014 do uchov\u00e1vacieho roztoku, aby sa rehydratovala. Hydratovan\u00e1 vrstva sa potom obnov\u00ed. Ak sa to nepodar\u00ed, je elektr\u00f3da v\u00e4\u010d\u0161inou trvalo po\u0161koden\u00e1.<\/p>\n<p>Meytec dod\u00e1va uchov\u00e1vac\u00ed roztok KCl v r\u00f4znych baleniach, okrem in\u00e9ho vo f\u013ea\u0161iach 250 ml a v praktick\u00fdch vreck\u00e1ch 20 ml.<\/p>\n<h2>Nezabudnite kalibrova\u0165<\/h2>\n<p>Aj pri dobrej \u00fadr\u017ebe potrebuj\u00fa pH a ORP elektr\u00f3dy pravideln\u00fa kalibr\u00e1ciu. Kalibr\u00e1cia udr\u017eiava elektr\u00f3du presn\u00fa a obmedzuje chyby merania. Ako je vysvetlen\u00e9 vy\u0161\u0161ie: kalibrujte v\u017edy <strong>po<\/strong> \u010disten\u00ed, aby sa offset a strmos\u0165 nastavili na \u010distom meracom povrchu.<\/p>\n<p><strong>Frekvencia:<\/strong><\/p>\n<ul>\n<li>Denn\u00e9 pou\u017e\u00edvanie \u2192 denn\u00e1 kalibr\u00e1cia<\/li>\n<li>Pr\u00edle\u017eitostn\u00e9 pou\u017e\u00edvanie \u2192 aspo\u0148 raz za t\u00fd\u017ede\u0148 alebo za mesiac<\/li>\n<li>Po vy\u010disten\u00ed elektr\u00f3dy<\/li>\n<li>Ak sa v\u00fdsledky ru\u010dn\u00e9ho testu odchy\u013euj\u00fa od merania elektr\u00f3dou<\/li>\n<\/ul>\n<p><strong>Pre pH elektr\u00f3dy<\/strong> pou\u017e\u00edvajte \u010derstv\u00fd <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-ph\/ph-7\/\">kalibra\u010dn\u00fd roztok<\/a>, minim\u00e1lne dva body: zvy\u010dajne <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-ph\/ph-4\/\">pH 4<\/a> a 7 alebo pH 7 a <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-ph\/ph-10\/\">pH 10<\/a>. Meytec pon\u00faka kalibra\u010dn\u00e9 roztoky v 250 ml, 60 ml a 20 ml.<\/p>\n<p><strong>Pre ORP elektr\u00f3dy<\/strong> pou\u017e\u00edvajte kalibra\u010dn\u00fd roztok ORP, napr\u00edklad <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-orp\/orp-475mv\/\">475&nbsp;mV<\/a>, <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-orp\/orp-468mv\/\">468&nbsp;mV<\/a> alebo <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-orp\/orp-650mv\/\">650&nbsp;mV<\/a>. Meytec ich dod\u00e1va v r\u00f4znych baleniach, okrem in\u00e9ho v praktick\u00fdch vreck\u00e1ch 20 ml.<\/p>\n<p>Presn\u00fd postup kalibr\u00e1cie v\u017edy n\u00e1jdete v n\u00e1vode svojho meracieho pr\u00edstroja. Pou\u017eit\u00fd kalibra\u010dn\u00fd roztok u\u017e po pribli\u017ene 20 min\u00fatach nie je presn\u00fd \u2014 vylejte ho a znova nepou\u017e\u00edvajte.<\/p>\n<p>So spr\u00e1vnou \u00fadr\u017ebou a pravidelnou kalibr\u00e1ciou bud\u00fa va\u0161e pH a ORP elektr\u00f3dy mera\u0165 spo\u013eahlivo cel\u00e9 roky \u2014 \u010di u\u017e ide o kri\u0161t\u00e1\u013eovo \u010dist\u00fd baz\u00e9n, alebo zdrav\u00e9 akv\u00e1rium. Meytec pon\u00faka kompletn\u00fd sortiment elektr\u00f3d, kalibra\u010dn\u00fdch roztokov, \u010distiacich prostriedkov a uchov\u00e1vac\u00edch roztokov, ktor\u00e9 v\u00e1m v tom pom\u00f4\u017eu.<\/p>\n<p>S\u00favisiace: <a href=\"\/sk\/kalibracne-roztoky\/kalibracne-roztoky-ph-orp\/\">kalibra\u010dn\u00e9 kity<\/a>, <a href=\"\/sk\/sondy-ph-orp-a-ec\/\">sondy<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>pH a ORP elektr\u00f3dy s\u00fa pre zdrav\u00fd baz\u00e9n alebo akv\u00e1rium nevyhnutn\u00e9. Bez \u00fadr\u017eby str\u00e1caj\u00fa presnos\u0165 v d\u00f4sledku usaden\u00edn, ne\u010dist\u00f4t a vysychania. Pravidelne ich \u010distite, uchov\u00e1vajte vlhk\u00e9 v roztoku KCl a kalibrujte \u010derstv\u00fdm kalibra\u010dn\u00fdm roztokom. Tak zostan\u00fa va\u0161e merania spo\u013eahliv\u00e9 a elektr\u00f3dy vydr\u017eia dlh\u0161ie. Meytec pon\u00faka v\u0161etky potrebn\u00e9 roztoky a pr\u00edslu\u0161enstvo na optim\u00e1lnu \u00fadr\u017ebu.<\/p>\n","protected":false},"author":0,"featured_media":18451,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[538],"tags":[],"class_list":["post-14935","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/posts\/14935","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/comments?post=14935"}],"version-history":[{"count":0,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/posts\/14935\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/media\/18451"}],"wp:attachment":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/media?parent=14935"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/categories?post=14935"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/tags?post=14935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}