{"id":14937,"date":"2026-07-15T18:50:00","date_gmt":"2026-07-15T16:50:00","guid":{"rendered":"https:\/\/staging.meytec.eu\/zoutmeter-voor-zwembad-zoutgehalte-meten\/"},"modified":"2026-10-21T15:30:32","modified_gmt":"2026-10-21T13:30:32","slug":"merac-soli-do-bazena-meranie-obsahu-soli","status":"publish","type":"post","link":"https:\/\/meytec.eu\/sk\/blogs\/blog\/merac-soli-do-bazena-meranie-obsahu-soli\/","title":{"rendered":"Mera\u010d soli do baz\u00e9na: meranie obsahu soli"},"content":{"rendered":"<h2>Baz\u00e9ny so so\u013enou elektrol\u00fdzou: ako funguj\u00fa?<\/h2>\n<p>Baz\u00e9n so slanou vodou rozhodne nie je baz\u00e9n bez chl\u00f3ru. Je to baz\u00e9n, v ktorom sa chl\u00f3r vyr\u00e1ba priamo na mieste z mal\u00e9ho mno\u017estva soli. Deje sa to prostredn\u00edctvom <strong>so\u013enej elektrol\u00fdzy<\/strong>: elektrolytick\u00e1 cela vo filtra\u010dnom okruhu premie\u0148a rozpusten\u00fd chlorid sodn\u00fd (NaCl) na pr\u00edrodn\u00fd chl\u00f3r (chl\u00f3rnan sodn\u00fd). Ke\u010f chl\u00f3r vykon\u00e1 svoju dezinfek\u010dn\u00fa pr\u00e1cu, zmen\u00ed sa op\u00e4\u0165 na so\u013e. Cyklus za\u010d\u00edna odznova.<\/p>\n<p>Ve\u013ek\u00e1 v\u00fdhoda: u\u017e nemus\u00edte chl\u00f3r kupova\u0165, prepravova\u0165 ani ru\u010dne d\u00e1vkova\u0165. Syst\u00e9m nepretr\u017eite vyr\u00e1ba mal\u00e9 mno\u017estvo chl\u00f3ru, \u010do zais\u0165uje rovnomern\u00fa kvalitu vody. Voda je navy\u0161e jemnej\u0161ia k poko\u017eke a o\u010diam a zmizne typick\u00fd z\u00e1pach chl\u00f3ru.<\/p>\n<h2>Pre\u010do mera\u0165 obsah soli?<\/h2>\n<p>So\u013en\u00e1 elektrol\u00fdza funguje len pri spr\u00e1vnom obsahu soli. Pr\u00edli\u0161 m\u00e1lo soli znamen\u00e1, \u017ee elektrolytick\u00e1 cela nedok\u00e1\u017ee vyrobi\u0165 dostatok chl\u00f3ru, \u010d\u00edm je ohrozen\u00e1 dezinfekcia. Pr\u00edli\u0161 ve\u013ea soli m\u00f4\u017ee po\u0161kodi\u0165 elektrolytick\u00fa celu a kovov\u00e9 \u010dasti baz\u00e9na.<\/p>\n<p>Obsah soli navy\u0161e nie je kon\u0161tantn\u00fd. Odparovan\u00edm, dop\u013a\u0148an\u00edm vodou z vodovodu, da\u017e\u010fom a sp\u00e4tn\u00fdm preplachom filtra sa koncentr\u00e1cia neust\u00e1le men\u00ed. Pravideln\u00e9 meranie je preto nevyhnutn\u00e9, aby syst\u00e9m fungoval spr\u00e1vne.<\/p>\n<h2>Ak\u00fd je ide\u00e1lny obsah soli?<\/h2>\n<p>Ide\u00e1lny obsah soli sa l\u00ed\u0161i pod\u013ea syst\u00e9mu a v\u00fdrobcu. Zhruba existuj\u00fa tri kateg\u00f3rie:<\/p>\n<table>\n<thead>\n<tr>\n<th>Typ syst\u00e9mu<\/th>\n<th>Koncentr\u00e1cia soli<\/th>\n<th>D\u00e1vkovanie na m\u00b3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0160tandardn\u00e1 so\u013en\u00e1 elektrol\u00fdza<\/td>\n<td>3 \u2013 4 g\/l (3.000 \u2013 4.000 ppm)<\/td>\n<td>3 \u2013 4 kg<\/td>\n<\/tr>\n<tr>\n<td>Hydrol\u00fdza \/ low salt<\/td>\n<td>1 \u2013 1,5 g\/l (1.000 \u2013 1.500 ppm)<\/td>\n<td>1 \u2013 1,5 kg<\/td>\n<\/tr>\n<tr>\n<td>Syst\u00e9m so slanou vodou Intex<\/td>\n<td>\u00b1 3,25 g\/l<\/td>\n<td>3,25 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pre porovnanie: morsk\u00e1 voda obsahuje asi 35 gramov soli na liter. Baz\u00e9n so slanou vodou je teda 8 a\u017e 10 -kr\u00e1t menej slan\u00fd \u2013 takmer to nec\u00edti\u0165.<\/p>\n<h3>Najpou\u017e\u00edvanej\u0161ie syst\u00e9my v Eur\u00f3pe a ich obsah soli<\/h3>\n<p>Eur\u00f3pskemu trhu dominuje nieko\u013eko v\u00fdrobcov, ka\u017ed\u00fd s vlastn\u00fdm odpor\u00fa\u010dan\u00fdm obsahom soli. Hayward so syst\u00e9mom AquaRite je jedn\u00fdm z naj\u010dastej\u0161\u00edch mien: \u0161tandardn\u00fd model funguje optim\u00e1lne pri <strong>3.200 ppm<\/strong> (asi 3,2 g\/l) s pracovn\u00fdm rozsahom 2.700 a\u017e 3.400 ppm. Hayward pon\u00faka aj variant Low Salt, ktor\u00e9mu sta\u010d\u00ed len <strong>1,5 g\/l<\/strong> .<\/p>\n<p>Zodiac (s\u00fa\u010das\u0165 Fluidra) je so syst\u00e9mami GenSalt roz\u0161\u00edren\u00fd v ju\u017enej Eur\u00f3pe. Modely GenSalt OE a OT vy\u017eaduj\u00fa odpor\u00fa\u010dan\u00fd obsah soli <strong>4 g\/l<\/strong>, s minimom 3 g\/l .<\/p>\n<p>AstralPool, takisto s\u00fa\u010das\u0165 Fluidra, dod\u00e1va syst\u00e9my Sel Pure. Tieto syst\u00e9my pracuj\u00fa s koncentr\u00e1ciou soli <strong>4 a\u017e 5 g\/l<\/strong> .<\/p>\n<p>Syst\u00e9my iChlor a IntelliChlor od Pentair sa \u010dasto pou\u017e\u00edvaj\u00fa v Eur\u00f3pe aj v Severnej Amerike. Ide\u00e1lny obsah soli je medzi <strong>3.200 a 3.400 ppm<\/strong> (3,2 \u2013 3,4 g\/l), s pracovn\u00fdm rozsahom 2.800 a\u017e 4.500 ppm .<\/p>\n<p>Sugar Valley sa odli\u0161uje syst\u00e9mami Oxilife, ktor\u00e9 kombinuj\u00fa hydrol\u00fdzu so so\u013enou elektrol\u00fdzou pri extr\u00e9mne n\u00edzkom obsahu soli, len <strong>1 a\u017e 1,5 g\/l<\/strong> .<\/p>\n<p>Poolex Turbo Salt je ob\u013e\u00fabenou vo\u013ebou pre men\u0161ie <a href=\"\/sk\/pouzitie\/bazen\/\">baz\u00e9ny<\/a>. Tento syst\u00e9m pracuje s n\u00edzkym obsahom soli <strong>3 a\u017e 3,5 g\/l<\/strong> .<\/p>\n<p>Intex Krystal Clear je najroz\u0161\u00edrenej\u0161\u00ed vstupn\u00fd model pre nadzemn\u00e9 baz\u00e9ny. Syst\u00e9m pracuje s odpor\u00fa\u010dan\u00fdm obsahom soli <strong>2,5 a\u017e 3,5 g\/l<\/strong> .<\/p>\n<p>Napokon s\u00fa tu e\u0161te zna\u010dky ako Waterco (Electrochlor: <strong>4.000 \u2013 6.000 ppm<\/strong>), Davey (ChloroMatic: <strong>3.000 \u2013 6.000 ppm<\/strong>, s mo\u017enos\u0165ou low-salt od 1.500 ppm) a MagnaPool (syst\u00e9m s miner\u00e1lnou so\u013eou bez sod\u00edka, na b\u00e1ze chloridu hore\u010dnat\u00e9ho a draseln\u00e9ho) .<\/p>\n<p><strong>Pozor:<\/strong> presn\u00e1 cie\u013eov\u00e1 hodnota je v\u017edy uveden\u00e1 v n\u00e1vode v\u00e1\u0161ho konkr\u00e9tneho syst\u00e9mu. Pre \u010do najpresnej\u0161ie d\u00e1vkovanie sa n\u00edm v\u017edy ria\u010fte.<\/p>\n<h2>Meranie a dop\u013a\u0148anie soli<\/h2>\n<p>Obsah soli jednoducho zmeriate <strong><a href=\"\/sk\/merac-soli-do-bazena.html\">digit\u00e1lnym mera\u010dom soli<\/a><\/strong>. Pr\u00edstroj ponorte do baz\u00e9novej vody, po\u010dkajte, k\u00fdm sa hodnota ust\u00e1li, a od\u010d\u00edtajte v\u00fdsledok v ppm alebo g\/l. 1.000 ppm zodpoved\u00e1 1 gramu na liter.<\/p>\n<p>Chcete obsah soli zv\u00fd\u0161i\u0165? Najprv si vypo\u010d\u00edtajte, ko\u013eko soli potrebujete:<\/p>\n<blockquote>\n<p><strong>Objem baz\u00e9na (m\u00b3) \u00d7 ch\u00fdbaj\u00faci rozdiel soli (kg\/m\u00b3) = celkov\u00e9 kg soli<\/strong><\/p>\n<\/blockquote>\n<p>Napr\u00edklad: baz\u00e9n s objemom 15 m\u00b3 s deficitom 1 kg\/m\u00b3 potrebuje 15 kg soli.<\/p>\n<p>V\u017edy pou\u017e\u00edvajte <strong>\u010dist\u00fa baz\u00e9nov\u00fa so\u013e<\/strong> (99,8 % NaCl) bez j\u00f3du alebo in\u00fdch pr\u00edsad. J\u00f3d m\u00f4\u017ee vodu v baz\u00e9ne sfarbi\u0165 do\u017elta a po\u0161kodi\u0165 elektrolytick\u00fa celu.<\/p>\n<h2>Mera\u010d soli Meytec a kalibr\u00e1cia<\/h2>\n<p>Meytec pon\u00faka <strong>mera\u010d soli GT-500S do baz\u00e9nov<\/strong>, digit\u00e1lny mera\u010d vodivosti s integrovan\u00fdm teplotn\u00fdm senzorom. Pr\u00edstroj meria koncentr\u00e1ciu soli od 0 do 10.000 ppm (0 \u2013 10 g\/l) a je navrhnut\u00fd \u0161peci\u00e1lne pre baz\u00e9ny so so\u013enou elektrol\u00fdzou.<\/p>\n<p>GT-500S sa \u013eahko pou\u017e\u00edva: stla\u010dte tla\u010didlo zapnutia\/vypnutia, ponorte elektr\u00f3du do vody, po\u010dkajte, k\u00fdm sa meranie ust\u00e1li, a od\u010d\u00edtajte hodnotu na displeji.<\/p>\n<h3>Kalibr\u00e1cia mera\u010da soli Meytec<\/h3>\n<p>Pre presn\u00e9 merania kalibrujte GT-500S pravidelne <strong><a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-ec\/ec-12880-s-cm\/\">kalibra\u010dn\u00fdm roztokom EC<\/a>.<\/strong><\/p>\n<ul>\n<li>Pou\u017eite <strong>12,88 mS\/cm<\/strong><\/li>\n<\/ul>\n<p><strong>Postup kalibr\u00e1cie:<\/strong><\/p>\n<ol start=\"1\">\n<li>Meraciu celu opl\u00e1chnite vodou z vodovodu alebo demineralizovanou vodou a otraste prebyto\u010dn\u00e9 kvapky.<\/li>\n<li>Do \u010distej n\u00e1dobky nalejte mal\u00e9 mno\u017estvo kalibra\u010dn\u00e9ho roztoku.<\/li>\n<li>Meraciu celu \u00faplne ponorte do roztoku.<\/li>\n<li>Po\u010dkajte, k\u00fdm sa hodnota ust\u00e1li, a podr\u017ete tla\u010didlo CAL stla\u010den\u00e9 5 a\u017e 6 sek\u00fand.<\/li>\n<li>Pr\u00edstroj automaticky rozpozn\u00e1 kalibra\u010dn\u00fd roztok a teraz sa nakalibruje.<\/li>\n<\/ol>\n<p>Na ka\u017ed\u00fa kalibr\u00e1ciu pou\u017eite \u010derstv\u00fd roztok a zvy\u0161ky vylejte. Zvy\u0161n\u00fa f\u013ea\u0161u v\u017edy dobre uzavrite.<\/p>\n<h2>Zhrnutie<\/h2>\n<p>So spr\u00e1vnym mera\u010dom soli, pravideln\u00fdm meran\u00edm a v\u010dasnou kalibr\u00e1ciou udr\u017e\u00edte svoj syst\u00e9m so\u013enej elektrol\u00fdzy v optim\u00e1lnej prev\u00e1dzke \u2013 pre \u010dist\u00fd, jemn\u00fd a bezpe\u010dn\u00fd baz\u00e9n. Meytec pon\u00faka mera\u010d soli do baz\u00e9na GT-500S a pr\u00edslu\u0161n\u00e9 kalibra\u010dn\u00e9 roztoky pre presn\u00e9 merania v ka\u017edej situ\u00e1cii.<\/p>\n<p>S\u00favisiace: <a href=\"\/sk\/meracie-pristroje\/merac-soli-do-bazena\/\">mera\u010d soli do baz\u00e9na<\/a>, <a href=\"\/sk\/kalibracne-roztoky\/kalibracny-roztok-ec\/ec-1413-s-cm\/\">EC 1413 \u00b5S\/cm<\/a>, <a href=\"\/sk\/sondy-ph-orp-a-ec\/orp-sonda\/\">ORP sonda pre baz\u00e9ny<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Baz\u00e9n so slanou vodou a so\u013enou elektrol\u00fdzou vyr\u00e1ba chl\u00f3r priamo na mieste z mal\u00e9ho mno\u017estva soli. Spr\u00e1vny obsah soli je k\u013e\u00fa\u010dov\u00fd: pr\u00edli\u0161 m\u00e1lo znamen\u00e1 nedostato\u010dn\u00fa dezinfekciu, pr\u00edli\u0161 ve\u013ea m\u00f4\u017ee po\u0161kodi\u0165 elektrolytick\u00fa celu. Preto pravidelne merajte digit\u00e1lnym mera\u010dom soli a dop\u013a\u0148ajte \u010distou baz\u00e9novou so\u013eou. Meytec pon\u00faka mera\u010d soli GT-500S do baz\u00e9nov. Tak udr\u017e\u00edte svoj syst\u00e9m v optim\u00e1lnej prev\u00e1dzke pre \u010dist\u00fa a jemn\u00fa baz\u00e9nov\u00fa vodu.<\/p>\n","protected":false},"author":0,"featured_media":18453,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[538],"tags":[],"class_list":["post-14937","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/posts\/14937","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/comments?post=14937"}],"version-history":[{"count":0,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/posts\/14937\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/media\/18453"}],"wp:attachment":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/media?parent=14937"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/categories?post=14937"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/tags?post=14937"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}