{"id":1064,"count":4,"description":"<h2>\u010cistiaci roztok na \u00fadr\u017ebu pH sondy a ORP sondy<\/h2><p>\u010cistiaci roztok na \u010distenie Va\u0161ej <a href=\"https:\/\/meytec.eu\/sk\/sondy-ph-orp-a-ec\/ph-sonda\/\">pH sondy<\/a> alebo <a href=\"https:\/\/meytec.eu\/sk\/sondy-ph-orp-a-ec\/orp-sonda\/\">ORP sondy<\/a>. Tento roztok je vyroben\u00fd \u0161peci\u00e1lne na odstra\u0148ovanie kontamin\u00e1cie z Va\u0161ej sondy.<\/p><ul><li>\u010cistite pred kalibr\u00e1ciou, nikdy po nej.<\/li><li>Maxim\u00e1lne 15 min\u00fat v roztoku. V pr\u00edpade potreby zopakujte.<\/li><li>Po pou\u017eit\u00ed \u010distiaceho roztoku d\u00f4kladne opl\u00e1chnite \u010distou vodou.<\/li><li>A\u017e potom kalibrujte spr\u00e1vnym kalibra\u010dn\u00fdm roztokom.<\/li><\/ul><h3>Baz\u00e9n<\/h3><p>V baz\u00e9ne zost\u00e1va na Va\u0161ej pH a ORP sonde film z rastu rias, ne\u010dist\u00f4t a ko\u017en\u00e9ho mazu. Tento film nie je v\u017edy vidie\u0165, ale pH sonda a ORP sonda kv\u00f4li nemu meraj\u00fa pomal\u0161ie. Najprv vy\u010disti\u0165, potom kalibrova\u0165 s pH 7 a pH 4 alebo pH 10. A ORP sondu s 475 mV alebo hodnotou, ktor\u00fa vy\u017eaduje V\u00e1\u0161 d\u00e1vkovac\u00ed syst\u00e9m.<\/p><h3>Hydrop\u00f3nia<\/h3><p>\u017diviny a riasy vytv\u00e1raj\u00fa na pH sonde povlak. pH sonda preto reaguje pomal\u0161ie a menej presne. Kr\u00e1tke namo\u010denie v \u010distiacom roztoku udr\u017e\u00ed sondu v optim\u00e1lnom stave.<\/p><h3>Laborat\u00f3rium<\/h3><p>Po meran\u00ed v bielkovin\u00e1ch, rozp\u00fa\u0161\u0165adl\u00e1ch alebo kontaminuj\u00facich l\u00e1tkach sa m\u00f4\u017ee diafragma upcha\u0165 alebo sonda zne\u010disti\u0165. pH sondu alebo ORP sondu vy\u010distite sk\u00f4r, ako ju znovu kalibrujete.<\/p><h3>Potraviny a n\u00e1poje<\/h3><p>Mlieko, v\u00edno, pivo, \u0161\u0165avy a om\u00e1\u010dky usadzuj\u00fa bielkoviny a cukor na diafragme a pH sonde. Bez \u010distenia je meranie pH pomal\u00e9 a nespo\u013eahliv\u00e9. Kr\u00e1tko namo\u010di\u0165 v \u010distiacom roztoku, opl\u00e1chnu\u0165, potom kalibrova\u0165.<\/p><h3>Akv\u00e1rium<\/h3><p>V akv\u00e1riu je na pH sonde alebo ORP sonde \u010dasto nevidite\u013en\u00fd film z rastu rias. Preto je ve\u013emi d\u00f4le\u017eit\u00e9 sondu pravidelne \u010disti\u0165 pre spr\u00e1vnu kalibr\u00e1ciu a meranie.<\/p><h2>Uchov\u00e1vanie \u010distiaceho roztoku<\/h2><p>Roztok uchov\u00e1vajte v p\u00f4vodnom, dobre uzavretom obale, v chlade a suchu pri 15\u201325 \u00b0C, chr\u00e1nen\u00fd pred mrazom a priamym slne\u010dn\u00fdm \u017eiaren\u00edm a mimo dosahu siln\u00fdch z\u00e1sad alebo oxida\u010dn\u00fdch \u010dinidiel.<\/p><h2>\u010cast\u00e9 ot\u00e1zky o \u010distiacom roztoku<\/h2><h3>Je to to ist\u00e9 ako kalibra\u010dn\u00fd roztok alebo uchov\u00e1vac\u00ed roztok KCl?<\/h3><p>Nie. \u010cisti\u010d pH alebo ORP sondu op\u00e4\u0165 vy\u010dist\u00ed t\u00fdm, \u017ee odstr\u00e1ni usadeniny z diafragmy a samotnej sondy. Kalibra\u010dn\u00fd roztok nastavuje pH meter alebo ORP meter. Uchov\u00e1vac\u00ed roztok KCl sl\u00fa\u017ei na dlh\u0161ie uchov\u00e1vanie alebo rehydrat\u00e1ciu sondy.<\/p><h3>M\u00f4\u017eem \u010disti\u0165 octom alebo demineralizovanou vodou?<\/h3><p>Nie. Demineralizovan\u00e1 voda oplachuje, bielkoviny a olej nerozp\u00fa\u0161\u0165a. Ocot m\u00f4\u017ee po\u0161kodi\u0165 diafragmu. Pou\u017e\u00edvajte len \u0161peci\u00e1lny \u010distiaci roztok na sondy.<\/p><h3>Ako \u010dasto m\u00e1m \u010disti\u0165?<\/h3><p>Pred ka\u017edou kalibr\u00e1ciou, ak vid\u00edte usadeniny, alebo po pou\u017eit\u00ed v mastn\u00fdch l\u00e1tkach, potravin\u00e1ch, n\u00e1pojoch... Svoju pH a ORP sondu \u010distite pravidelne pre r\u00fdchlej\u0161ie a stabilnej\u0161ie meranie.<\/p><h3>M\u00f4\u017ee sonda zosta\u0165 v \u010disti\u010di cez noc?<\/h3><p>Nie. Maxim\u00e1lne 15 min\u00fat naraz. Dlh\u0161ie nam\u00e1\u010danie nepom\u00e1ha. V\u017edy d\u00f4kladne opl\u00e1chnite.<\/p><h3>Kalibrujem pred \u010disten\u00edm alebo po \u0148om?<\/h3><p>Po \u010disten\u00ed. Nikdy pred n\u00edm.<\/p><h3>M\u00f4\u017eem \u010distiaci roztok pou\u017ei\u0165 na v\u0161etky pH sondy a ORP sondy?<\/h3><p>\u00c1no. Tento \u010distiaci roztok je vhodn\u00fd pre v\u0161etky typy a zna\u010dky pH sond a ORP sond. Samozrejme je vhodn\u00fd aj pre Va\u0161e pH metre a ORP metre. Tento \u010distiaci roztok teda m\u00f4\u017eete pou\u017ei\u0165 na v\u0161etky svoje ob\u013e\u00faben\u00e9 syst\u00e9my Sugar Valley, Hayward, Zodiac, AstralPool, Bayrol, Hanna, Milwaukee, Mettler, WTW alebo Bluelab. Pri \u0161peci\u00e1lnom ISFET si pozrite n\u00e1vod.<\/p><p>Balenia:<\/p><ul><li><a href=\"https:\/\/meytec.eu\/sk\/cistiaci-roztok-elektrody.html\">\u010cistiaci roztok 250 ml<\/a><\/li><li><a href=\"https:\/\/meytec.eu\/sk\/cistiaci-roztok-ph-sonda.html\">\u010cistiaci roztok 60 ml<\/a> (pred\u00e1va sa v sade 5x60 ml)<\/li><\/ul><p>Objednajte si \u010distiaci roztok, ktor\u00fd Va\u0161a pH sonda alebo ORP sonda potrebuje. M\u00e1te e\u0161te pochybnosti alebo ot\u00e1zky? <a href=\"https:\/\/meytec.eu\/sk\/zakaznicky-servis\/\">Kontaktujte n\u00e1s<\/a>.<\/p><\/article>","link":"https:\/\/meytec.eu\/sk\/kalibracne-roztoky\/cistiaci-roztok\/","name":"\u010cistiaci roztok","slug":"cistiaci-roztok","taxonomy":"product_cat","parent":1041,"meta":[],"menu_order":0,"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/product_cat\/1064","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/product_cat"}],"about":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/taxonomies\/product_cat"}],"up":[{"embeddable":true,"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/product_cat\/1041"}],"wp:post_type":[{"href":"https:\/\/meytec.eu\/sk\/wp-json\/wp\/v2\/product?product_cat=1064"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}